Partial Discharge TEV Sensor: A Smarter Solution for Switchgear Online Monitoring

In modern substations and distribution networks, insulation failure inside switchgear and ring main units (RMUs) remains one of the leading causes of unexpected outages. As utilities continue to improve power system reliability, online partial discharge monitoring has become an essential part of preventive maintenance strategies.

Among different monitoring technologies, the partial discharge TEV sensor has become widely adopted because it can detect early insulation defects without interrupting equipment operation. By combining TEV and ultrasonic detection technologies, utilities can identify hidden discharge activity before it develops into serious failures.

partial discharge TEV sensor installed on medium voltage switchgear
partial discharge TEV sensor installed on medium voltage switchgear

Why Partial Discharge Monitoring Matters

Partial discharge (PD) is a localized electrical discharge caused by insulation deterioration, loose connections, moisture, or aging components. In enclosed metal switchgear, these discharges may remain undetected for long periods until insulation breakdown occurs.

Traditional periodic inspections often cannot capture intermittent PD activity. Online monitoring sensors provide continuous condition assessment and allow maintenance teams to respond before faults escalate.

This is especially important for:

What Is a Partial Discharge TEV Sensor?

A partial discharge TEV sensor is designed to detect transient earth voltage signals generated by internal discharge activity inside metal-clad switchgear.

When partial discharge occurs, high-frequency electromagnetic pulses propagate along the metal enclosure surface. TEV sensors capture these signals and convert them into measurable data for analysis.

Modern systems often integrate ultrasonic AA sensing technology together with TEV detection. This dual-detection approach significantly improves diagnostic accuracy.

The Huwor dual-technology sensor integrates:

  • TEV detection 
  • Ultrasonic AA detection 
  • Intelligent diagnostic capability
  • Wireless or wired communication
  • Online real-time monitoring
dual technology partial discharge TEV and ultrasonic AA sensor
dual technology partial discharge TEV and ultrasonic AA sensor

Dual Detection Technology Improves Accuracy

One major advantage of combining TEV and ultrasonic technologies is the ability to analyze both electrical and mechanical discharge characteristics simultaneously.

TEV Detection

TEV monitoring focuses on high-frequency electromagnetic signals generated by internal discharges.

Key parameters include:

  • Frequency range: 1–100 MHz
  • Measurement range: 0–70 dB

TEV technology is particularly effective for enclosed metal switchgear and RMUs.

Ultrasonic AA Detection

Ultrasonic sensing captures acoustic emissions generated during discharge activity.

Key parameters include:

  • Resonant frequency: 40 kHz
  • Measurement range: -10–75 dB

Ultrasonic monitoring is highly useful in noisy electromagnetic environments and can help verify discharge sources.

Together, these technologies provide more reliable insulation assessment compared with single-parameter monitoring systems.

TEV and ultrasonic partial discharge detection principle diagram
TEV and ultrasonic partial discharge detection principle diagram

Strong Anti-Interference Performance in Complex Environments

Substations and switching stations often contain strong electromagnetic interference. Reliable sensor performance requires advanced noise suppression capability.

The sensor uses:

  • Electromagnetic shielding
  • Signal filtering
  • Noise suppression algorithms
  • Stable signal acquisition technology

These features help ensure accurate monitoring even in challenging electrical environments.

Intelligent Diagnosis and Early Warning

Modern substations increasingly rely on intelligent monitoring systems rather than manual inspections alone.

The integrated data analysis module can:

  • Analyze discharge patterns in real time
  • Identify abnormal PD characteristics
  • Automatically trigger alarms
  • Support predictive maintenance decisions

This allows maintenance personnel to locate insulation risks earlier and reduce unplanned outages.

Easy Installation Without Power Interruption

One of the practical benefits of this partial discharge TEV sensor is its simple installation method.

The sensor typically supports:

  • Magnetic adsorption installation
  • Live installation without shutdown
  • Fast on-site deployment
  • Minimal maintenance requirements

Because no complex modification of existing equipment is required, utilities can quickly upgrade older substations with online monitoring capability.

online installation of partial discharge TEV sensor in substation
online installation of partial discharge TEV sensor in substation

Communication and Power Supply Options

The sensor supports both wireless and wired deployment schemes.

Wireless Version

  • LoRa communication
  • Built-in lithium battery

Wired Version

  • RS485 communication
  • DC24V power supply

This flexibility makes the solution suitable for different substation architectures and monitoring requirements.

Technical Specifications

ItemSpecification
TEV Frequency Range1–100 MHz
TEV Measurement Range0–70 dB
AA Resonant Frequency40 kHz
AA Measurement Range-10–75 dB
Wireless CommunicationLoRa
Wired CommunicationRS485
Wireless Power SupplyBuilt-in Lithium Battery
Wired Power SupplyDC24V
Operating Temperature-40°C to +85°C
Operating Humidity5–95% RH

Typical Applications

The partial discharge TEV sensor is widely used in:

  • Medium-voltage switchgear
  • Ring main units (RMUs)
  • Distribution substations
  • Switching stations
  • Industrial power systems
  • Smart grid monitoring projects

Continuous online monitoring helps utilities improve equipment reliability, reduce maintenance costs, and prevent unexpected failures.

partial discharge monitoring applications in RMU and switchgear
partial discharge monitoring applications in RMU and switchgear

Conclusion

As power systems move toward intelligent operation and predictive maintenance, the demand for reliable online partial discharge monitoring continues to grow.

A dual-technology partial discharge TEV sensor combining TEV and ultrasonic AA detection provides more accurate fault identification, stronger anti-interference performance, and easier installation for modern substations and switchgear systems.

For utilities seeking long-term equipment reliability and safer grid operation, integrated TEV and ultrasonic monitoring solutions are becoming an increasingly practical choice.