News

Transformer internal components with floating potential areas where partial discharge activity can occur.

What Causes Partial Discharge in Transformer? Common Sources and Practical Insights

Partial discharge in transformers does not occur randomly. In most cases, it is the result of specific insulation weaknesses or installation-related issues that develop over time. Understanding what causes partial discharge in transformer systems is the first step toward preventing insulation failure and unplanned outages. Rather than focusing on test values alone, identifying the root causes of […]

What Causes Partial Discharge in Transformer? Common Sources and Practical Insights Read More »

Engineers performing partial discharge testing on a power transformer using portable monitoring equipment.

Partial Discharge in Transformer: Causes, Risks, and Practical Detection Methods

Introduction Partial discharge in transformer insulation is one of the earliest indicators of internal electrical deterioration. Although it may not cause immediate failure, partial discharge (PD) gradually weakens insulation strength and significantly increases the risk of unexpected transformer outages. For utilities and industrial operators, understanding how partial discharge forms, how it affects transformer reliability, and how

Partial Discharge in Transformer: Causes, Risks, and Practical Detection Methods Read More »

Model GIS and UHF measurement system

Identification of Partial Discharge Sources in GIS Using UHF Time-Domain Analysis

Introduction Gas Insulated Switchgear (GIS) has become a key component in modern power systems due to its compact structure, high reliability, and excellent environmental resistance. However, the fully enclosed design of GIS also makes internal insulation diagnostics extremely challenging. Among various insulation defects, partial discharge (PD) is widely recognized as an early indicator of insulation degradation

Identification of Partial Discharge Sources in GIS Using UHF Time-Domain Analysis Read More »

Engineer using an acoustic sensor to locate partial discharge inside a power transformer.

Understanding Partial Discharge Testing in Power Transformers: A Practical Engineering Guide

Maintaining the reliability of a power transformer goes far beyond oil sampling or routine electrical checks. One diagnostic technique that has gradually become indispensable is Partial Discharge (PD) testing. Although PD itself is not always catastrophic, its early detection can prevent insulation breakdown, unplanned outages, and expensive transformer failures. This article provides an engineer-friendly, experience-based

Understanding Partial Discharge Testing in Power Transformers: A Practical Engineering Guide Read More »

Principle Diagram of Multi-Sensor Technology for TEV, Ultrasound, HFCT, and UHF Detection Modes

The New Standard for PD Detection: Multi-Functional Partial Discharge Detector Secures Power Systems Globally

In modern electrical power systems, Partial Discharge (PD) detection is a critical process for assessing the integrity of electrical insulation. Deterioration of insulation can lead to reduced equipment lifespan, and in severe cases, catastrophic insulation failure, resulting in explosions or major outages. Therefore, selecting a high-precision, highly efficient Partial Discharge detection equipment is essential for ensuring long-term

The New Standard for PD Detection: Multi-Functional Partial Discharge Detector Secures Power Systems Globally Read More »

Close-up of high-voltage equipment insulation undergoing Partial Discharge (PD) degradation.

What is Partial Discharge (PD)? Understanding the Root Cause of Electrical Insulation Failure and Its Detection

Introduction: The Silent Threat to Electrical Integrity In the world of high-voltage (HV) electrical infrastructure, longevity and reliability hinge entirely on the integrity of the insulation system. Yet, deep within cables, switchgear, and transformers, a subtle, often undetectable form of degradation is taking place: Partial Discharge (PD). PD is not a complete failure, but rather

What is Partial Discharge (PD)? Understanding the Root Cause of Electrical Insulation Failure and Its Detection Read More »

High Voltage Partial Discharge (PD) Online Monitoring Systems

Prevent Arc Flash: High Voltage Partial Discharge (PD) Online Monitoring Systems

The Silent Killer in High Voltage Assets: Partial Discharge In mission-critical infrastructure like high-voltage (HV) cables, Gas Insulated Switchgear (GIS), and power transformers, the integrity of the insulation system is paramount. However, over time, voids, contaminants, or manufacturing defects within the insulation begin to break down under electrical stress. This process manifests as Partial Discharge

Prevent Arc Flash: High Voltage Partial Discharge (PD) Online Monitoring Systems Read More »

Visual depiction of electrical treeing and insulation degradation due to chronic Partial Discharge.

Partial Discharge Monitoring Device Selection: Expert Tips to Avoid False Alarms and Pinpoint Insulation Faults

Introduction: For any facility manager or power grid engineer, nothing is more stressful than an unexpected high-voltage (HV) equipment failure. Even with routine preventive maintenance (PM) schedules, catastrophic insulation breakdowns can seemingly occur out of the blue. The truth is, most major failures are preceded by a series of tiny, silent warnings—a phenomenon known as

Partial Discharge Monitoring Device Selection: Expert Tips to Avoid False Alarms and Pinpoint Insulation Faults Read More »

The ultrasonic sensors and high-frequency current sensors are being prepared for testing.

Substation Partial Discharge Online Monitoring System Successfully Shipped

Our latest partial discharge (PD) online monitoring project for a substation has successfully completed all stages of production, functional testing, and quality inspection. The entire system—consisting of high-frequency current sensors, ultrasonic PD sensors, IED concentrators, and accompanying accessories—has now entered the shipment phase and will soon arrive on site for installation. Strict Quality Control to

Substation Partial Discharge Online Monitoring System Successfully Shipped Read More »

A batch of arrester current digital remote meters arranged neatly.

Surge Arrester Online Monitoring Devices Completed and Shipped to Substation Projects

Our latest production run of digital leakage-current transmission meters—used for surge arrester online monitoring in substations—has now been completed and is on its way to project sites across multiple regions. These meters provide continuous, real-time visibility into the condition of substation surge arresters by tracking key parameters such as leakage current and operating status. The

Surge Arrester Online Monitoring Devices Completed and Shipped to Substation Projects Read More »